MBRAUN Spares And Parts

Sort By:  
MB-AC-purge (PLC) Retrofit (1518023)
Additional purge function of one antechamber with inert gas. The connected antechamber can be purged in overpressure with inert gas instead of using the standard vacuum process, PLC controlled. The function vent with box gas and MB-SCH-PLC functions are also included. The standard process vacuum/refilling with gas from the glovebox is still possible. Please note: The quality of the gas supply has to be 5.0 or better. Included: Pressure regulator, pipework, valves for gas inlet and gas outlet as well as overpressure valve for antechamber, pressure sensors. ***** Available only for Unilab, Labmaster, MB-20-G, MB-200-G
MB-AC-Purge (manual) Upgrade (1518022)
Upgrade: Additional purge function of one antechamber with inert gas. The connected antechamber can be purged in overpressure with inert gas instead of using the standard vacuum process, with manual hand valves. The standard process vacuum/refilling with gas from the glovebox is still possible. Please note: The quality of the gas supply has to be 5.0 or better. Included: Pressure regulator, pipework, valves for gas inlet and gas outlet as well as overpressure valve for antechamber.
MB-AC-vent external (PLC) Retrofit (1518021)
Refilling of one antechamber with fresh gas. The connected antechamber is vented by fresh gas from the gas supply instead of refilling with gas from the glovebox, PLC controlled, included: automatic antechamber control (MB-SCH-PLC). The standard refilling process with glovebox atmosphere is not possible anymore. Please note: The quality of the gas supply has to be 5.0 or better. Included: Pressure regulator, pipework, valves for gas inlet and gas outlet as well as overpressure valve for antechamber, pressure sensors. ***** Available only for Unilab, Labmaster, MB-20-G, MB-200-G
MB-AC-vent external (manual) Upgrade (1518020)
Refilling of one antechamber with fresh gas (upgrade). The connected antechamber is vented by fresh gas from the gas supply instead of refilling with gas from the glovebox with manual hand valves. A pressure equilibration from the glovebox is not done. The standard refilling process with glovebox atmosphere is not possible anymore. Please note: The quality of the gas supply has to be 5.0 or better. Included: Pressure regulator, pipework, valves and overpressure valve for antechamber
MB-AUTO-AC_tc_Labstar/Unilab Retrofit (1518019)
Automatic antechamber control for main antechambers (upgrade) Operation: time controlled evacuation / refill with factory defined parameters. Parameter: No. of cycles for evacuation and refill Evacuation (time controlled) Intermediate refill (time controlled) Refill to final pressure (time controlled)
MB-SCH-PLC-3DV-2PD Retrofit (1518018)
Automatic ante chamber PLC-control unit including sensors and software. Ante chamber control, 3 doors including interlock, automatic lifting mechanism for 2 doors
MB-SCH-PLC-2DV-2PD Retrofit (1518017)
Automatic ante chamber PLC-control unit including sensors and software. Ante chamber control, 2 doors including interlock, automatic lifting mechanism for 2 doors
MB-SCH-PLC-2DV-1PD Retrofit (1518016)
Automatic antechamber PLC-control unit including sensors and software. Antechamber control, 2 doors including interlock, automatic lifting mechanism for 1 door
Automatic antechamber, 1xAD, 1xPD
MB-SCH-PLC-3-DV Retrofit (1518015)
Automatic ante chamber PLC-control unit including sensors and software. Ante chamber control, 3 doors including interlock for the antechamber or the oven to avoid failure of operation.
MB-SCH-PLC-2-DV Retrofit (1518014)
Automatic antechamber PLC-control unit including sensors and software. Antechamber control, 2 doors including mechanical interlock for the antechamber or the oven to avoid failure of operation.
MB-SCH-PLC Upgrade (1518013)
Automatic antechamber control for M.Braun (upgrade) Main antechambers, pressure controlled. Programable antechamber cycles: - no. of cycles - intermediate vacuum for refill - ultimate vacuum Operation: through the Touch Panel
Antechamber automatic, pressure controlled
MB-AAC-LOCK-MINI-AC-DV (1518012)
Automatic mini-antechamber control with door locks. PLC-controlled antechamber control unit including sensors and software. Ante chamber control, 2 doors including mechanical interlock for the antechamber or the oven to avoid failure of operation.
MB-SCH-T-390-800-CYL - Upgrade (1518005)
Upgrade: Antechamber, T-style, three vacuum doors; with swinging mechanism, gas spring damping; Including sliding tray on telescopic rails. Dimensions: 390mm (d) 800mm (l).
MB-SCH-390-1T-L upgrade (1518000)
Antechamber Upgrade, dia. = 390, length = 600, mounted mounted on left side panel
MB-SCH-390-1T-R Upgrade (1518001)
Antechamber Upgrade, dia. = 390, length = 600, mounted on right side panel
MB-SCH-390-L_Unilab Upgrade (1518002)
Antechamber Upgrade, dia. = 390, length = 600, mounted on left side panel
MB-SCH-390-R_Unilab Upgrade (1518003)
Antechamber Upgrade, dia. = 390, length = 600, mounted on right side panel
MB-SCH-T-390-600-CYL - Upgrade (1518004)
Upgrade: Ante chamber, dia. = 390, length = 600, t-shape, three vacuum doors
MB-VOH-MINI-150 (1518008)
Upgrade: Mini-antechamber oven, Heating via heating jacket / heating coils outsideup to max. 150
Heatable Mini AC, 150
MB-MINI-AC-150-L Upgrade (1518010)
Mini antechamber Upgrade Diameter 150 mm, length 400 mm Type: 1/3 inside, 2/3 outside the box Cover: Hinged cover inside and outside Operation: manual, 3-way valve Incl. sliding tray
Per Page      101 - 120 of 394