MBraun Inert Glove-Box Technology
MB-LMF-2/40-REG stand alone Retrofit (1518603)
Upgrade for existing system Unit for removal of solvent contaminations from the glovebox atmosphere (LMF) Principle: adsorption Adsorber: Molecular sieve; regenerable Loading: approx. 8 kg Operation modes: a) Inline: circulation of the atmosphere via the LMF with continuous removal b) Bypass: with manual valves, the LMF can be by-passed from the circulation, e.g. during exchange of the adsorber, without breaking the circulation of the gas purifier
MB-BS-200 Retrofit (1518602)
Box purging system - Upgrade Unit for inerting (purging) of the workspace with inertgas Operation: via operation panel of the gas purifier Valves PLC-controlled Flow rate: max. 200 l/min; incl. manual regulation valve for reduction of the gas flow Functions: - Purging ON / OFF - Max. purging time programmable (0-999 min) The O2 and H2O concentrations are readable during purge (if sensors are installed).
box purge unit 200l/min
MB-Heat exchanger Upgrade for Unilab (1518601)
Upgrade: for the integration in the gas pipework to the UNILAB glovebox inside the gas purifier unit. The working gas will be cooled effectively through this device; thus the temperature inside the glovebox remains comfortable for the operator. required water flow rate: 3-5 l/min rated cooling power: approx. 800 W
MB-Easyclean-LTBL-88 External Upgrade (1518504)
Retrofit kit: Dust cleaner for cleaning MB-Gloveboxes and removal of particles/dust. Filter unit is installed outside the glovebox. Valves for filter change: Uncoupling the Filter housings from Glovebox and Inertisation of the filter housing after filter change. Main components: - Blower (gas-tight) for suction of the particles with a throughput of approx. 84 m
MB-Easyclean-LTBL-88 Internal Upgrade (1518503)
Retrofit kit: Vacuum cleaner for cleaning MB gloveboxes and removal of particles / dust Filter unit is installed inside the glovebox mounted Main components: - Blower (gas-tight) for suction of the particles with a throughput of approx. 84m
MB-Easyclean-LTBL-22 Internal Upgrade (1518502)
Retrofit kit: Vacuum cleaner for cleaning MB gloveboxes and removal of particles / dust Filter unit is installed inside the glovebox mounted. Main components: - Blower (gas-tight) for suction of the particles with a throughput of approx. 20m
First Care Kit - Ambidextrous gloves (1518501)
Buy a set and save 10%. First care waer part kit consisting of: - 1 pair of ambidextrous gloves (Art. 1515001) - 2 dust filters - 1 liter oil for vacuum pump - 1 gloveport cover The kit is delivered in a reusable MBRAUN plastic transport box.
MB-AC-purge (PLC) Retrofit (1518023)
Additional purge function of one antechamber with inert gas. The connected antechamber can be purged in overpressure with inert gas instead of using the standard vacuum process, PLC controlled. The function vent with box gas and MB-SCH-PLC functions are also included. The standard process vacuum/refilling with gas from the glovebox is still possible. Please note: The quality of the gas supply has to be 5.0 or better. Included: Pressure regulator, pipework, valves for gas inlet and gas outlet as well as overpressure valve for antechamber, pressure sensors. ***** Available only for Unilab, Labmaster, MB-20-G, MB-200-G
MB-STORAGE-RACKS-MID Storage racks, Size M (1518024)
Shelf rail with 5 open fronted storage boxes to hang on the back wall of your glovebox instead of a shelf. - Suitable for a shelf with a width of 1000mm - Back wall bracket: 880mm - Load capacity per box 2kg - Maximum capacity: 5 viewing boxes (L x W x H) 234 x150x122mm Installation cannot be done in an inert atmosphere.
MB-STORAGE-RACKS-SMALL Storage racks, Size S (1518025)
Shelf rail with 8 open fronted storage boxes to hang on the back wall of your glovebox instead of a shelf. - Suitable for a shelf with a width of 1000mm - Back wall bracket: 880mm - Load capacity per box 1.3kg - Maximum capacity: 9 viewing boxes (L x W x H) 168x103x76mm Installation cannot be done in an inert atmosphere. Side walls all around prevent objects from falling down to the Glovebox floor.
MB-RKI-80 Retrofit (1518200)
Cooling unit for tempering the box atmosphere (upgrade) Mounted at box ceiling Cooling capacity: 1,08 kW Stand alone control unit. ***** For Unilab: only in combination with heat exchanger (1500152).
MB-RKI-200 Retrofit (1518201)
Cooling unit for tempering the box atmosphere (Upgrade) Mounted at box ceiling Cooling capacity: 2,60 kW Stand alone control unit. (please note: requires glovebox with minimum width of 1500 mm) ***** For Unilab: only in combination with heat exchanger (1500152).
MB GS-35 DIN R Upgrade, incl. sidepanel (1518202)
Upgrade: Freezer (box integrated) from +10
Freezer, -35 Deg C, left
myMBRAUN Interface upgrade (1518302)
Upgrade: Hardware to be installed in electrical cabinet to allow data communication between the glovebox and myMBRAUN App. ***** Customer should supply network details to MBRAUN, to define the communication settings before shipping ***** Included: Communication kit, new board with updated Rev.5 hardware ***** For Labstar/Unilab produced between February 2014 and January 2015, please contact our service dept. to check the revision number. Please contact our service dept. to check your version before ordering. ***** Requires installation through M. Braun Service Additional installation fees apply.
MB-HC-SE1 Upgrade (1518400)
Upgrade: The MB-HC-SE1 analyzer is designed for the detection and monitoring of VOCs (volatile organic compounds) in inert gas or air. Using a photo ionization detector (PID) it is capable of measuring concentrations down to the lower ppm-range (optional: ppb-range). Calibrated for iso-Butene, sensitivities for different other substances can be obtained from tabulated conversion factors. The output voltage signal is scaled 0-10V for 0 to 6000ppm iso-Butene (optional 4-20mA output available). Mounted directly into the circulation piping using the standard KF40 flange. ***** Note: For the intended use (monitoring of a solvent trap = LMF) there is no necessity for an accurate ppm value of a special solvent nor for strict linear response. Typically, mixtures of different substances are to be handled by the LMF and the concentration is low as long as the filter is active. A distinct increase in the signal will indicate exhaust of the filtering material. The PID technology with its combination of low detection limit and large dynamic range is ideally fitted for this application.
myMBRAUN Interface upgrade (1518303)
Upgrade: Hardware to be installed in electrical cabinet to allow data communication between the glovebox and myMBRAUN App. ***** Customer should supply network details to MBRAUN, to define the communication settings before shipping ***** Included: communication kit, IBH Link S7++ ***** For Unilab produced before February 2014 and for Labmaster/MB20(0)G Please contact our service dept. to check your version before ordering. ***** Requires installation through MBRAUN Service Additional installation fees apply.
Tube with anchor (Kalrez) for article: 1517200 (1517202)
Suitable for solvent applications. (Original item number: 2610239)
myMBRAUN Interface upgrade (1518301)
Upgrade: Hardware to be installed in electrical cabinet to allow data communication between the glovebox and myMBRAUN App. ***** Customer should supply network details to MBRAUN, to define the communication settings before shipping ***** Included: communication kit ***** For Labstar/Unilab: systems produced after January 2015. Please contact our service dept. to check your version before ordering. ***** Requires installation through M. Braun Service Additional installation fees apply.
Replacement for DMR controller (1518300)
Kit for retrofitting the existing DMR (pressure measurement control) of the glovebox with Eurotherm controller.
Consisting of:
1x regulator
1x pressure sensor
1x cable, wiring diagram controller, manual
1x Blind cover
(Original item number: 2600301)