MBraun Inert Glove-Box Technology
Analyzer MB-MO-SE1, 0-500ppm, 4-20mA (1511611)
The MB-MO-SE-1 analyzer has been designed to monitor the atmosphere of MBRAUN Systems for residual Moisture content. Please note that the sensor head must be coated regularly with 85% phosphoric acid. The measuring range is 0 to 500 ppm. (Original item number: 1500686)
Analyzer MB-UGP-He in Ar, 0-100% (1511645)
Analyzer for measuring helium in argon atmosphere. Measuring range: 0-100% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000264)
MB-LTBL-88 Blower 400V 3ph (1512203)
Former description: MB-BL-02 Only suitable for 400V systems without frequency converter. Use with: Gas cleaning Unilab/ MB20/ Labmaster (SP&DP) Clean-Jet MB-PA-60 (particle separator) MB-ROTRON Refitkit (Original article number: 9002834)
MB-LTBL-88 Blower 230V 3ph (1512201)
Former description: MB-BL-01 Only suitable in combination with a frequency converter. Use with: Gas cleaning Unilab/ MB20/ Labmaster (SP&DP) Clean-Jet MB-PA-60 (particle separator) MB-ROTRON Refitkit (Original article number: 9002832)
MB-LTBL-22 Blower 24 V (1512200)
Use with: MB-Easyclean-BL8 Gas cleaning MB10 (Original article number: 7090527)
Siemens frequency connverter with panel (1512003)
For processing we need the MBRAUN project number, and the BMK number (yellow Sticker =equipment identification) (Original item number: 2601317)
Frequency converter for Systems before 2014 (1512002)
Suitable for gloveboxes built before 2014 with the following circulation blower: - MB-BL-01 - MB-LTBL-88 When ordering, the project number of your MBRAUN system is required. (Original item number: 2700675)
MB-N2-SE1, 0-1000ppm, 230VAC (1511660)
This analyzer is used to detect and monitor the N2 concentration in an Ar or He atmosphere. Measuring range: 0-1000ppm The control of all functions and Parameter monitoring takes place through an integrated control computer. The operation is controlled by a touch panel. The analyzer is operated via a closed loop system with the sample gas of the box. We recommend to integrate this system by a MBRAUN technician.
Analyzer MB-UGP-Hex in N2, 0-1000ppm (1511651)
Analyzer for measuring hexane in nitrogen atmosphere. Measuring range: 0-1000ppm Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000256)
Analyzer MB-UGP-CO2, 0-20% (1511650)
Analyzer for measuring carbon dioxide in the box atmosphere. Measuring range: 0-20% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000258)
Analyzer MB-UGP-CO2, 0-5000ppm (1511649)
Analyzer for measuring carbon dioxide in the box atmosphere. Measuring range: 0-5000ppm Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000255)
Analyzer MB-UGP-CO2, 0-10% (1511648)
Analyzer for measuring carbon dioxide in the box atmosphere. Measuring range: 0-10% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000253)
Analyzer MB-UGP-CO2, 0-100% (1511647)
Analyzer for measuring carbon dioxide in the box atmosphere. Measuring range: 0-100% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 1500273)
Analyzer MB-UGP-He in N2, 0-30% (1511646)
Analyzer for measuring helium in nitrogen atmosphere. Measuring range: 0-30% Operating voltage: 110-240VAC The UGB is supplied with the sample gas of the box by a closed loope system. The measured value can be displayed via the system control (SPS) of MBRAUN standard systems or above the optionally available independent MBRAUN SSD-DIS combination monitor. Calibration must be performed by MBRAUN will be. (Original item number: 6000617)
Analyzer MB-OX-EC, 0-1000ppm, 0-10V, Gas with CO2 (1511622)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. (Original item number: 1500716)
Analyzer MB-OX-EC, 0-25% O2, 4-20mA (1511625)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. Measuring range: 0 to 25% (Original item number: 1500820)
Analyzer MB-OX-EC, 0-25%, 0-10V (1511624)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. Measuring range: 0 to 25% (Original item number: 1500819)
Analyzer MB-OX-EC, 0-1000ppm, 4-20mA, Gas with CO2 (1511623)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. (Original item number: 1500818)
Analyzer MB-HC-SE1, 0-6000 ppm,0-10V (1511630)
The MB-HC-SE1 analyzer is designed for monitoring
of VOCs (volatile organic compounds) in
inert gases or air.
Since the sensor is calibrated for hexane, the
Solvent detectable depending on RF-factor.
Measuring range: 0-6000ppm
The measured value can be displayed via the system control (SPS)
of MBRAUN standard systems or above the
optionally available independent MBRAUN
SSD-DIS combination monitor.
Calibration must be performed by MBRAUN
will be.
(Original item number: 1500678)
Analyzer MB-OX-EC, 0-1000ppm,4-20mA, Gas w/o CO2 (1511621)
Electrochemical Oxygen analyzer to be used when atmosphere is not dry or when a lot of solvent vapors are present. The analyzer MB-OX-EC monitors the oxygen content in inert gases. The analyzer can be used in combination with the system control (PLC) of MBRAUN standard systems or as standalone oxygen-measuring-system with the optionally available MBRAUN SSD-DIS combi-monitor. (Original item number: 1500816)